{"{0} cups":"{0}杯","{0} ft² / {1} m²":"{0}ft² / {1}m²","{0} g / {1} oz":"{0}g / {1}oz","{0} hours / {1} minutes":"{0}小时 / {1}分钟","{0} kcal/day":"{0}千卡/天","{0} litres/day":"{0}升/天","{0} US pints/day":"{0}美制品脱/天","{0} V":"{0}V","{0} V / {1}%":"{0}V / {1}%","{0} W":"{0}W","{0} W / {1} BTU/h":"{0}W / {1}BTU/h","{0} W / {1} kW":"{0}W / {1}kW","{0} W / {1} W":"{0}W / {1}W","{0} W load; {1} Wh rated capacity; {2} hours runtime. DoD {3}%, inverter {4}%, Peukert exponent {5}, rating {6} hours. Constant load/voltage assumption; standby draw excluded.":"负载{0}W；额定容量{1}Wh；运行时间{2}小时。放电深度{3}%，逆变器效率{4}%，Peukert指数{5}，额定时长{6}小时。假设负载和电压恒定；不包括待机功耗。","{0} Wh":"{0}Wh","{0} Wh / {1} Ah at {2} V":"{0}Wh / {1}Ah，电压{2}V","{0}: {1} {2}/year; {3} kg CO₂/year.":"{0}：{1}{2}/年；{3}kg CO₂/年。","20 °C / 68 °F":"20°C / 68°F","3% guidance":"3%指导值","5% guidance":"5%指导值","75 °C / 167 °F":"75°C / 167°F","AAHA 2021: RER and life-stage factors":"AAHA 2021：RER和生命阶段系数","Add {0}: {1} W running / {2} W starting":"添加{0}：运行{1}W / 启动{2}W","Add at least one device and enter a total running load greater than zero.":"请至少添加一个设备，并输入大于零的总运行负载。","Add at least one insulation layer with a positive thickness and thermal value.":"请至少添加一层厚度和热工参数均大于零的保温层。","Add custom device":"添加自定义设备","Add layer":"添加层","Add to list":"添加到列表","Adult activity":"成年动物活动量","AHAM 2005 selection guide, Table 1, published by Cornell Cooperative Extension. Conditions describe the space during warm, humid weather; no ceiling-height assumption is specified. Volume input only recovers floor area.":"AHAM 2005选型指南表1，由Cornell Cooperative Extension发布。条件描述的是温暖、潮湿天气下的空间；未指定层高假设。输入体积只能还原地面面积。","AHAM estimate: {0} US pints/day = {1} litres/day. Area {2} m²; chart column {3} ft². Rated at 80 °F / 60% RH; not a current DOE pint rating.":"AHAM估算：{0}美制品脱/天 = {1}升/天。面积{2}m²；图表列{3}ft²。额定条件为80°F / 60%RH；不是现行DOE品脱额定值。","All prices and CO₂ factors are your inputs. Blank fields must be filled; placeholders are examples, not local tariffs. Currency changes the label only. Enter oil price per kWh of fuel: price per litre or gallon ÷ kWh per litre or gallon.":"所有价格和CO₂系数均由你输入。空白字段必须填写；占位示例不是当地费率。货币只会改变标签。请输入每kWh燃料的燃油价格：每升或每加仑价格÷每升或每加仑的kWh数。","Aluminium":"铝","Amp-hours × volts (Ah × V)":"安时×伏特（Ah × V）","Annual heating cost and CO₂":"年度供暖成本和CO₂","Annual heating fuel bill":"年度供暖燃料账单","Annual useful heat (kWh)":"年度有效热量（kWh）","Annual useful heat (million BTU)":"年度有效热量（百万BTU）","Appliance":"家用电器","Area (ft²)":"面积（ft²）","Area (m²)":"面积（m²）","Area, load, prices, factors and allowances cannot be negative.":"面积、负载、价格、系数和余量不能为负数。","Area: {0} m² / {1} ft². The {2} ft² column is used. Below 500 ft², use the smallest column; above 2500 ft², seek a separate assessment.":"面积：{0}m² / {1}ft²。使用{2}ft²列。低于500ft²时使用最小列；高于2500ft²时请另行评估。","Ask your vet to confirm an appropriate weight, calorie target and complete diet, especially for kittens, puppies, illness or weight loss. For weight loss, enter the vet-agreed ideal weight. This is a starting estimate; monitor body condition and adjust with your vet. Do not restrict a growing pet's food for weight loss.":"请让兽医确认合适的体重、热量目标和完整饮食，尤其是幼猫、幼犬、生病或需要减重的宠物。减重时请输入兽医认可的理想体重。这只是初步估算；请监测体况并与兽医一起调整。不要为了减重限制生长期宠物的食物。","Assumes steady current, equal conductors, unity power factor and negligible AC reactance. Three-phase voltage is line-to-line. This is not an ampacity, protection, earth-fault or installation safety check. A drop at or above the supply voltage means the model is outside a usable operating range.":"假设电流稳定、导体相同、功率因数为1且交流电抗可忽略。三相电压为线电压。这不是载流量、保护、接地故障或安装安全检查。压降达到或超过供电电压，表示模型超出可用运行范围。","Assumes uniform layers in series and steady heat flow. Excludes framing bridges, air leakage, moisture and compression. Surface resistance starts at zero; a complete wall or roof calculation needs appropriate surface films and all layers. Floor U-values also depend on ground geometry.":"假设各层均匀串联且热流稳定。不包括框架热桥、漏风、湿气和压缩。表面热阻从零开始；完整的墙体或屋顶计算需要适当的表面膜和全部层。地板U值还取决于地面几何形状。","AUD":"AUD","AWG":"AWG","AWG size":"AWG规格","Balanced three-phase AC":"平衡三相交流","Bill price per fuel unit":"每燃料单位账单价格","Body weight (kg)":"体重（kg）","Body weight (lb)":"体重（lb）","Boiler and resistance efficiencies must be greater than zero and no more than 100 percent.":"锅炉和电阻加热效率必须大于0且不超过100%。","CAD":"CAD","Calculated estimate":"计算估算值","Calculation":"计算","Calories reserved for treats (%)":"零食预留热量（%）","Capacity for target runtime":"目标运行时间所需容量","Capacity rating duration (hours)":"容量额定时长（小时）","Capacity units":"容量单位","Capacity, size, efficiency, density and weight must be greater than zero.":"容量、尺寸、效率、密度和重量必须大于零。","Cat food: wet and dry mix":"猫粮：湿粮和干粮混合","Chart source":"图表来源","Choose an AWG size from 0000 to 40.":"请选择0000至40之间的AWG规格。","Circuit":"电路","CO₂ factor (kg per input kWh)":"CO₂系数（每输入kWh的kg数）","Comparison limit":"比较限值","Condition":"条件","Conductor cross-section (mm²)":"导体截面积（mm²）","Conductor material":"导体材料","Conductor size units":"导体尺寸单位","Conductor temperature":"导体温度","Conductor voltage drop":"导体压降","Constant load (W)":"恒定负载（W）","Constant running load":"恒定运行负载","Copper":"铜","Copy result":"复制结果","Cost/year ({0})":"成本/年（{0}）","CPSC: portable generator safety":"CPSC：便携式发电机安全","Cross-section (mm²)":"截面积（mm²）","cups":"杯","Currency label":"货币标签","Current (A)":"电流（A）","Custom device":"自定义设备","Custom material":"自定义材料","Daily energy (MER)":"每日能量（MER）","Dampness without a dehumidifier":"无除湿机时的潮湿程度","DC, two conductors":"直流，双导体","Dehumidifier capacity":"除湿机容量","Depth of discharge (%)":"放电深度（%）","Derived λ (W/m·K)":"推导λ（W/m·K）","Device {0}":"设备{0}","Device name":"设备名称","DOE rating change":"DOE额定值变化","DOE uninsulated attic ceiling recommendation: R-{0}. Additional material R to reach this: {1}. This attic guidance does not apply to every wall or floor.":"DOE无保温阁楼天花板建议值：R-{0}。达到该值所需的额外材料R值：{1}。此阁楼指导值不适用于所有墙体或地板。","Dog food and daily calories":"狗粮和每日热量","Dry food label (kcal/cup)":"干粮标签（kcal/杯）","Dry food label (kcal/kg)":"干粮标签（kcal/kg）","Dry food per day":"每日干粮","Efficiency (%)":"效率（%）","Electric resistance":"电阻加热","ENERGY STAR gives approximate old → new portable ratings: 30 → 20, 40 → 25, 50 → 30, 70 → 40–45 US pints/day. These examples vary by model.":"ENERGY STAR给出的便携式设备旧→新额定值近似对应为：30→20、40→25、50→30、70→40–45美制品脱/天。这些示例因型号而异。","Energy units":"能量单位","England Part L element":"英格兰Part L构件","Enter a number":"请输入数字","Enter a percentage greater than zero and no more than 100.":"请输入大于0且不超过100的百分比。","Enter finite numbers within the supported range.":"请输入支持范围内的有限数值。","Estimated runtime":"预计运行时间","EUR":"EUR","Example: 0.10":"示例：0.10","Example: 0.15":"示例：0.15","Example: 0.20":"示例：0.20","Existing heater efficiency (%)":"现有加热器效率（%）","Expanded polystyrene":"膨胀聚苯乙烯","Extremely wet: wet floor or drying laundry":"极度潮湿：湿地板或晾晒衣物","Extruded polystyrene":"挤塑聚苯乙烯","Fibreglass batt":"玻璃纤维毡","Floor":"地板","Floor area":"地面面积","Floor area (ft²)":"地面面积（ft²）","Floor area (m²)":"地面面积（m²）","Food label (kcal/cup)":"食物标签（kcal/杯）","Food label (kcal/kg)":"食物标签（kcal/kg）","Food label energy units":"食物标签能量单位","Food per day":"每日食物","For a bill in kWh, enter 1 kWh per unit. For litres or gallons, enter the supplier's energy per litre or gallon. Use only the heating share of the bill and exclude standing charges, cooking and other uses.":"对于以kWh计费的账单，请输入每单位1kWh。对于升或加仑，请输入供应商提供的每升或每加仑能量值。只使用账单中的供暖部分，不包括固定费用、烹饪和其他用途。","Formula: area = volume ÷ height; choose the next AHAM area column at or above {0} ft². Litres/day = pints/day × 0.473176473.":"公式：面积 = 体积÷高度；选择大于或等于{0}ft²的下一个AHAM面积列。升/天 = 品脱/天×0.473176473。","Formula: bill-derived heat = bill ÷ price per fuel unit × kWh per unit × old efficiency. Input kWh = useful heat ÷ SCOP or efficiency; annual cost = input kWh × price; CO₂ = input kWh × factor.":"公式：账单推导热量 = 账单÷每燃料单位价格×每单位kWh×旧效率。输入kWh = 有效热量÷SCOP或效率；年度成本 = 输入kWh×价格；CO₂ = 输入kWh×系数。","Formula: DC/single-phase ΔV = 2 × I × L × ρ/A; balanced three-phase ΔV = √3 × I × L × ρ/A. L is one-way metres; A is mm². Drop % = 100 × ΔV ÷ supply voltage. ρ(T) = ρ20 × [1 + α × (T − 20)].":"公式：直流/单相ΔV = 2×I×L×ρ/A；平衡三相ΔV = √3×I×L×ρ/A。L为单程米数；A为mm²。压降% = 100×ΔV÷供电电压。ρ(T) = ρ20×[1 + α×(T − 20)]。","Formula: layer R = thickness in inches × R per inch; layer RSI = thickness in metres ÷ λ. RSI = sum of layers + surface RSI; 1 US R = 0.1761101838 RSI; U = 1 ÷ RSI; heat loss = U × area × ΔT.":"公式：单层R值 = 英寸厚度×每英寸R值；单层RSI = 米厚度÷λ。RSI = 各层之和 + 表面RSI；1 US R = 0.1761101838 RSI；U = 1÷RSI；热损失 = U×面积×ΔT。","Formula: RER = 70 × weight in kg^0.75; MER = RER × multiplier; food kcal = MER × (1 − treat share/100); grams = food kcal × 1000 ÷ kcal/kg; cups = food kcal ÷ kcal/cup.":"公式：RER = 70×体重kg^0.75；MER = RER×系数；食物kcal = MER×(1 − 零食占比/100)；克数 = 食物kcal×1000÷kcal/kg；杯数 = 食物kcal÷kcal/杯。","Formula: running total = Σ(quantity × running watts); extra surge = max(starting watts − running watts, 0) among active devices; peak = running total + largest extra surge; recommended rating = peak × (1 + margin/100).":"公式：运行总功率 = Σ（数量×运行功率）；额外浪涌 = 活动设备中的max（启动功率−运行功率，0）；峰值 = 运行总功率 + 最大额外浪涌；建议额定值 = 峰值×（1 + 余量/100）。","Formula: Wh = Ah × V; standard runtime = Wh × DoD × inverter efficiency ÷ watts. Reverse capacity = hours × watts ÷ (DoD × efficiency). Percentages are divided by 100.":"公式：Wh = Ah×V；标准运行时间 = Wh×放电深度×逆变器效率÷瓦数。反推容量 = 小时数×瓦数÷（放电深度×效率）。百分比需除以100。","Fuel bill excluding fixed charges":"不含固定费用的燃料账单","g":"g","Gas boiler":"燃气锅炉","GBP":"GBP","Generator estimate: {0} W / {1} kW peak rating, {2} W continuous with margin. Running {3} W + largest extra surge {4} W, then {5}% margin. One motor starts at a time; verify nameplates and generator ratings.":"发电机估算：峰值额定值{0}W / {1}kW，含余量的连续功率{2}W。运行功率{3}W + 最大额外浪涌{4}W，再加{5}%余量。一次启动一台电机；请核对铭牌和发电机额定值。","Generator running and surge rating":"发电机运行和浪涌额定值","Heat demand source":"热需求来源","Heat loss":"热损失","Heat pump":"热泵","Heavy work":"高强度活动","Historical AHAM chart: US pints removed in 24 hours":"历史AHAM图表：24小时去除的美制品脱数","Historical AHAM rating":"历史AHAM额定值","IEC 60364-5-52 catalogue":"IEC 60364-5-52目录","Imperial / US":"英制 / 美制","Inactive / obesity prone":"不活跃 / 易肥胖","Indoor / inactive adult":"室内 / 不活跃成年动物","Input kWh/year":"输入kWh/年","Intact adult":"未绝育成年动物","Inverter efficiency (%)":"逆变器效率（%）","kcal/cup → cups":"kcal/杯→杯数","kcal/kg → grams":"kcal/kg→克数","Kettle":"电水壶","kg CO₂/year":"kg CO₂/年","Kitten":"幼猫","kWh of heat":"热量kWh","kWh per billed unit":"每计费单位kWh","Laptop":"笔记本电脑","Layer {0}":"第{0}层","Layered insulation and heat loss":"分层保温和热损失","Lead-acid: apply Peukert's effect":"铅酸电池：应用Peukert效应","Life stage / feeding plan":"生命阶段 / 喂食计划","Light work":"轻度活动","Lighting":"照明","Line-to-line supply voltage (V)":"线电压（V）","local currency":"当地货币","Local currency":"当地货币","Loose cellulose":"松散纤维素","Material":"材料","Material R (US)":"材料R值（美制）","Material R = {0}; total RSI = {1} m²·K/W; U = {2} W/m²·K; heat loss = {3} W. R sums thickness × R/in; U = 1/RSI; Q = U × area × temperature difference. Surface RSI = {4}; bridges and air leakage excluded.":"材料R值 = {0}；总RSI = {1}m²·K/W；U = {2}W/m²·K；热损失 = {3}W。R值为厚度×R/英寸之和；U = 1/RSI；Q = U×面积×温差。表面RSI = {4}；不包括热桥和漏风。","Material RSI: {0}. Total R including surface resistance: {1}. Area {2} m² / {3} ft²; ΔT {4} K / {5} °F.":"材料RSI：{0}。包括表面热阻的总R值：{1}。面积{2}m² / {3}ft²；ΔT{4}K / {5}°F。","Material table: University of Maryland Extension":"材料表：University of Maryland Extension","MER multiplier (editable)":"MER系数（可编辑）","Metric":"公制","Million BTU of heat":"百万BTU热量","Mineral wool":"矿棉","Mix formula: wet kcal = food kcal × wet share/100; dry kcal = food kcal − wet kcal. The split is by calories, not weight or volume.":"混合公式：湿粮kcal = 食物kcal×湿粮占比/100；干粮kcal = 食物kcal−湿粮kcal。分配依据是热量，不是重量或体积。","Moderate work":"中度活动","Moderately damp: occasional musty smell":"中度潮湿：偶尔有霉味","NEC 210.19(A) informational note recommends about 3% on a branch circuit and 5% total feeder plus branch for reasonable operation; an informational note is guidance. IEC 60364-5-52 Annex G describes voltage-drop guidance by supply and load type, commonly 3% lighting / 5% other uses on public low-voltage supplies. Check local adopted rules and the entire circuit path.":"NEC 210.19(A)信息注建议支路约为3%，馈线加支路总计5%，以实现合理运行；信息注属于指导。IEC 60364-5-52附录G按供电和负载类型说明压降指导值，公共低压供电通常为照明3% / 其他用途5%。请核对当地采用的规定和完整电路路径。","Neutered adult":"已绝育成年动物","NFPA 70 catalogue":"NFPA 70目录","NIST copper tables":"NIST铜材表","Nominal battery voltage (V)":"电池标称电压（V）","Normal adult activity":"成年动物正常活动量","Oil boiler":"燃油锅炉","One-way length (ft)":"单程长度（ft）","One-way length (m)":"单程长度（m）","Operate portable generators outdoors, at least 20 ft (6.1 m) from the home, with exhaust away from openings. Never use indoors or in a garage. Use carbon monoxide alarms and an electrician-installed transfer arrangement for household circuits.":"请在室外运行便携式发电机，与住宅至少保持20ft（6.1m）距离，并使排气口远离开口。切勿在室内或车库中使用。请使用一氧化碳报警器，并由电工为家用电路安装转换装置。","Optional surface resistance (m²·K/W)":"可选表面热阻（m²·K/W）","Part L editions and scope":"Part L版本和适用范围","Part L here means England, Volume 1, 2021 edition with 2023 amendments, Table 4.1: new-dwelling limiting values, not tighter notional design targets. The 2026 edition takes effect in March 2027, or September 2027 for higher-risk work, subject to transition rules. Other UK nations have their own requirements.":"此处Part L指英格兰第1卷2021版及2023年修订版表4.1：新住宅限值，而不是更严格的假定设计目标。2026版将于2027年3月生效；高风险工程则于2027年9月生效，具体受过渡规则约束。英国其他地区有各自的要求。","Part L new-dwelling limiting U: {0} W/m²·K; calculated U: {1}. Difference from limit: {2} W/m²·K (positive means above limit). This is an illustrative comparison, not a compliance determination.":"Part L新住宅限值U：{0}W/m²·K；计算U：{1}。与限值的差异：{2}W/m²·K（正值表示高于限值）。这只是示例性比较，不代表合规判定。","Peukert equation: scope and limitations":"Peukert方程：范围和限制","Peukert exponent (1–2)":"Peukert指数（1–2）","Peukert is a constant-current approximation for lead-acid, using nominal voltage and an entered rated discharge duration (often 20 hours). High current reduces available capacity; low-current extrapolation can overestimate it. DoD is applied as a planning share of predicted full-discharge time. Use the manufacturer's discharge curves for final sizing; lithium normally uses k = 1.":"Peukert是针对铅酸电池的恒流近似模型，使用标称电压和输入的额定放电时长（通常为20小时）。高电流会降低可用容量；低电流外推可能高估容量。放电深度作为预测完全放电时间的规划比例应用。最终选型请使用制造商的放电曲线；锂电池通常使用k = 1。","Peukert option: t = d × H × (C × η ÷ (P × H))^k; reverse C = P × H ÷ η × (t ÷ (d × H))^(1/k). C is rated Wh at H hours; d is DoD, η efficiency, P load and k exponent. Unadjusted runtime: {0} hours.":"Peukert选项：t = d×H×(C×η÷(P×H))^k；反推C = P×H÷η×(t÷(d×H))^(1/k)。C是H小时下的额定Wh；d为放电深度，η为效率，P为负载，k为指数。未调整运行时间：{0}小时。","Polyurethane":"聚氨酯","Price per input kWh":"每输入kWh价格","Puppy 4 months or older":"4个月或以上幼犬","Puppy under 4 months":"未满4个月幼犬","Quantity":"数量","R per inch":"每英寸R值","R per inch (US)":"每英寸R值（美制）","Rated capacity (Ah)":"额定容量（Ah）","Rated capacity (Wh)":"额定容量（Wh）","Rated capacity: {0} Wh / {1} Ah at {2} V. DoD {3}%; efficiency {4}%. Starting surges, inverter standby consumption, ageing, cold temperatures and voltage cutoffs are excluded. Add standby draw to the load and check the inverter's power limit separately.":"额定容量：{0}Wh / {1}Ah，电压{2}V。放电深度{3}%；效率{4}%。不包括启动浪涌、逆变器待机功耗、电池老化、低温和电压截止。请将待机功耗加入负载，并单独检查逆变器功率限制。","Receiving voltage estimate":"受端电压估算值","Reference resistivities (Ω·mm²/m): copper 0.01724 at 20 °C and 0.020966426 at 75 °C, α = 0.00393/K; aluminium 0.02828 at 20 °C and 0.03434606 at 75 °C, α = 0.0039/K. The 75 °C values are linear estimates; alloys and stranding vary.":"参考电阻率（Ω·mm²/m）：铜在20°C时为0.01724、75°C时为0.020966426，α = 0.00393/K；铝在20°C时为0.02828、75°C时为0.03434606，α = 0.0039/K。75°C数值为线性估算；合金和绞线结构会有所不同。","Refrigerator":"冰箱","Remove device {0}":"移除设备{0}","Remove layer {0}":"移除第{0}层","Repair leaks and water ingress first. This sizing guide does not model ventilation, temperature, infiltration or ongoing moisture generation.":"请先修复漏水和进水问题。此选型指南不模拟通风、温度、渗透或持续产生的湿气。","Required rated capacity":"所需额定容量","RER {0} kcal/day; MER {1} kcal/day. RER = 70 × {2} kg^0.75; MER = RER × {3}. Treats {4}%; food {5} kcal/day; dry/food portion {6} {7}/day; wet {8} g/day. Confirm with your vet; label calorie density is assumed.":"RER{0}kcal/天；MER{1}kcal/天。RER = 70×{2}kg^0.75；MER = RER×{3}。零食{4}%；食物{5}kcal/天；干粮/食物部分{6}{7}/天；湿粮{8}g/天。请与兽医确认；假设采用标签上的热量密度。","Roof":"屋顶","Room height (ft)":"房间高度（ft）","Room height (m)":"房间高度（m）","Room measurement":"房间测量值","Room volume (ft³)":"房间体积（ft³）","Room volume (m³)":"房间体积（m³）","Room volume and height":"房间体积和高度","Running load / extra surge":"运行负载 / 额外浪涌","Running W":"运行W","Running watts per device":"每台设备运行功率","Runtime from capacity":"按容量计算运行时间","SCOP 3.0 means 3 kWh of useful heat per kWh of electricity over a season. Try 2–4 as an editable sensitivity range, not a guarantee: climate, flow temperature, defrosting and backup heating affect performance. Use a measured seasonal value when available. The two electric systems share one tariff and grid factor.":"SCOP 3.0表示一个采暖季中每kWh电力产生3kWh有效热量。可尝试将2–4作为可编辑的敏感性范围，但这不是保证：气候、供水温度、除霜和备用加热都会影响性能。如有实测季节值，请优先使用。两种电力系统共用一个费率和电网系数。","Seasonal COP (SCOP)":"季节性能系数（SCOP）","Single-phase AC":"单相交流","Sizing margin (%)":"选型余量（%）","Starting factors: neutered adult 1.2, intact adult 1.4, indoor/inactive 1.0, kitten 2.5, weight loss 0.8. AAHA adult ranges are 1.2–1.4 neutered and 1.4–1.6 intact; indoor is an inactive estimate, not a universal requirement.":"起始系数：已绝育成年动物1.2、未绝育成年动物1.4、室内/不活跃1.0、幼猫2.5、减重0.8。AAHA成年动物范围为已绝育1.2–1.4、未绝育1.4–1.6；室内值是不活跃估算值，不是普遍要求。","Starting factors: neutered adult 1.6, intact 1.8, inactive 1.2; puppy under 4 months 3.0, older puppy 2.0; weight loss 1.0. Work examples use 2.0, 3.0 and 6.0 within AAHA's light (1.6–2), moderate (2–5) and heavy (5–11) ranges. Activity selects a factor; it is not multiplied by the life-stage factor.":"起始系数：已绝育成年动物1.6、未绝育1.8、不活跃1.2；未满4个月幼犬3.0、较大幼犬2.0；减重1.0。活动量示例使用2.0、3.0和6.0，分别处于AAHA轻度（1.6–2）、中度（2–5）和高强度（5–11）范围内。活动量用于选择系数，不与生命阶段系数相乘。","Starting W":"启动W","Suggested continuous rating with margin":"含余量的建议连续额定值","Suggested peak rating with margin":"含余量的建议峰值额定值","Supply voltage (V)":"供电电压（V）","System":"系统","Target runtime (hours)":"目标运行时间（小时）","Temperature difference (°C / K)":"温差（°C / K）","Temperature difference (°F)":"温差（°F）","The chart covers up to 2500 square feet. Split larger spaces or ask a professional.":"图表最多覆盖2500平方英尺。更大的空间请分开计算或咨询专业人士。","Thermal property":"热工参数","Thickness (in)":"厚度（in）","Thickness (mm)":"厚度（mm）","This compares the same annual useful heat. Excludes installation, maintenance, standing charges and embodied emissions. Choose direct CO₂ or lifecycle factors consistently; CO₂e factors give CO₂e results. Boiler efficiencies must be 0–100%; electricity resistance starts at 100%.":"此比较基于相同的年度有效热量。不包括安装、维护、固定费用和隐含排放。请始终一致地选择直接CO₂系数或生命周期系数；使用CO₂e系数时结果为CO₂e。锅炉效率必须为0–100%；电阻加热从100%开始。","This is the historical 80 °F (26.7 °C), 60% RH rating. From June 2019, DOE tests portable units at 65 °F (18.3 °C), 60% RH. Lower pint ratings can describe comparable machines. Do not use a fixed conversion factor or compare this result directly with a modern label.":"这是历史上的80°F（26.7°C）、60%RH额定值。自2019年6月起，DOE在65°F（18.3°C）、60%RH条件下测试便携式设备。较低的品脱额定值可能对应性能相当的设备。不要使用固定换算系数，也不要将此结果直接与现代标签比较。","Total RSI (m²·K/W)":"总RSI（m²·K/W）","Total starting watts per device":"每台设备总启动功率","Typical appliance examples (editable after adding)":"典型家用电器示例（添加后可编辑）","Typical appliance examples are illustrative planning values. Replace them with nameplate ratings and measured starting watts; they are not product specifications.":"典型家用电器示例仅为规划参考值。请用铭牌额定值和实测启动功率替换；这些不是产品规格。","Typical insulation values: replace with product data":"典型保温值：请替换为产品数据","Typical R per inch is editable. Switching to λ converts the same thermal property. Replace these examples with the product's declared value.":"典型每英寸R值可编辑。切换到λ会换算相同的热工参数。请用产品声明值替换这些示例。","U (W/m²·K)":"U（W/m²·K）","UK Government: seasonal COP definition":"英国政府：季节性能系数定义","Units":"单位","University of Victoria: conductor properties":"University of Victoria：导体属性","Unmargined peak: {0} W. Starting watts means total draw during start, not extra draw. Assumes one device starts while the rest run; simultaneous starts require a larger allowance. Choose a machine meeting both continuous and surge ratings, with suitable surge duration, voltage and outlets. Watts do not capture apparent-power requirements or altitude derating.":"未加余量的峰值：{0}W。启动功率指启动期间的总功耗，不是额外功耗。假设一台设备启动时其他设备仍在运行；同时启动需要更大的余量。请选择同时满足连续和浪涌额定值，且浪涌持续时间、电压和插座合适的设备。瓦数无法反映视在功率要求或海拔降额。","UPS and battery-bank runtime":"UPS和电池组运行时间","US DOE climate zone":"美国DOE气候区","US DOE climate-zone recommendations":"美国DOE气候区建议","Usable energy before Peukert adjustment":"Peukert调整前的可用能量","USD":"USD","Use a device list":"使用设备列表","Use a Peukert exponent from 1 to 2 and a positive rated discharge time.":"请使用1至2之间的Peukert指数和大于零的额定放电时长。","Use the kcal/cup value for that exact food and the manufacturer's cup measure. Cups cannot be converted to grams without that food's density. Treats should generally be no more than 10% of total calories; choose a complete diet for the life stage. Pregnancy, lactation and medical diets need an individual veterinary plan.":"请使用该确切食物的kcal/杯值和制造商的杯量标准。没有该食物的密度，杯数无法换算为克数。零食通常不应超过总热量的10%；请为相应生命阶段选择完整饮食。怀孕、哺乳和医疗饮食需要个体化的兽医计划。","Used: {0} m / {1} ft, {2} A, {3} mm², {4} V, {5} °C. Resistivity {6} Ω·mm²/m; one conductor resistance {7} Ω/m. Difference from {8}% guidance: {9} percentage points.":"已使用：{0}m / {1}ft、{2}A、{3}mm²、{4}V、{5}°C。电阻率{6}Ω·mm²/m；单根导体电阻{7}Ω/m。与{8}%指导值的差异：{9}个百分点。","Useful annual heat demand":"年度有效热需求","Useful heat: {0} kWh / {1} million BTU per year.":"有效热量：{0}kWh / {1}百万BTU/年。","Useful heat: {0} kWh/year. Input energy = heat ÷ SCOP or efficiency; cost = input kWh × price; CO₂ = input kWh × factor. Fixed costs and installation excluded. {1}":"有效热量：{0}kWh/年。输入能量 = 热量÷SCOP或效率；成本 = 输入kWh×价格；CO₂ = 输入kWh×系数。不包括固定费用和安装。{1}","Very damp: persistent damp patches":"非常潮湿：持续存在潮湿斑块","Vet-supervised weight loss":"兽医监督下减重","Voltage drop":"电压降","Voltage drop {0} V ({1}%); receiving voltage {2} V; one-way length {3} m; ρ = {4} Ω·mm²/m at {5} °C. ΔV = {6} × I × L × ρ/A; unity power factor, no reactance.":"电压降{0}V（{1}%）；受端电压{2}V；单程长度{3}m；{5}°C时ρ = {4}Ω·mm²/m。ΔV = {6}×I×L×ρ/A；功率因数为1，无电抗。","Wall":"墙体","Water pump":"水泵","Water removal":"除水量","Watt-hours (Wh)":"瓦时（Wh）","Weight: {0} kg / {1} lb. RER: {2} kcal/day. Multiplier: {3}. Treat allowance: {4} kcal/day; main food: {5} kcal/day. Food calorie densities are editable label examples, not recommendations for a particular product.":"体重：{0}kg / {1}lb。RER：{2}kcal/天。系数：{3}。零食额度：{4}kcal/天；主食：{5}kcal/天。食物热量密度是可编辑的标签示例，不是针对特定产品的建议。","Wet food and treat shares must each be from 0 to 100 percent.":"湿粮和零食占比必须分别在0%到100%之间。","Wet food label (kcal/kg)":"湿粮标签（kcal/kg）","Wet food per day":"每日湿粮","Wet share of food calories (%)":"食物热量中的湿粮占比（%）","Wet: {0} kcal/day at {1} kcal/kg; dry: {2} kcal/day at {3} on the selected label scale.":"湿粮：{0}kcal/天，热量密度为{1}kcal/kg；干粮：{2}kcal/天，采用所选标签单位下的{3}。","Wet: condensation or seepage":"潮湿：冷凝或渗水","WSAVA: nutritional assessment and monitoring":"WSAVA：营养评估和监测","Zone {0}":"区域{0}","λ (W/m·K)":"λ（W/m·K）"}